Designed to Deliver

Engineered for precision through simplicity. A clear sample interface, integrated visual feedback, and structured software guidance ensure each analysis is performed consistently and correctly. Purposeful ergonomics and single-use sensor streamline operation from preparation to cleanup, keeping the focus on results, not procedure.

Elegant Tools

LanthaCell

Our proprietary sensors use metal organic frameworks (MOFs) containing lanthanides to detect solvent purity. These materials fluoresce under UV light, producing application-specific colorimetric responses that map to analyte purity or water content. Each sensor comes in an environmentally isolated, single-use cuvette, for clean handling.

LanthaLux

Our purpose-built fluorimeter combines stable UV excitation with calibrated optical capture to quantify fluorescence ratios with high repeatability. Engineered for targeted purity analysis, it translates subtle color shifts into clear, numerical data, transferring wirelessly to a connected laptop. A compact body, rechargeable battery, and low-maintenance design keep operation dependable and easy day after day.

LuxCtrl

Our software provides crystal-clear, step-by-step instructions tailored to each application. Stops that prevent progress until steps are completed, which reduces user error. Output is a single number that directly corresponds to purity or water content.

Engineered for Everyday

Rapid Results

Get quantitative answers in mere minutes, not hours or days. Make decisions on the spot with rapid, reliable analysis that keeps your work moving forward.

Clear Insights

Data that speaks for itself. Easy to see, consistent, and reproducible. Guided software reduces complexity and guards against human error.

Effortless

Seamless from sample to answer with minimal prep, and a 10-minute learning curve. Anyone can generate reliable data without specialized training.

Streamlined Testing

Compact tech that saves resources. Low startup and maintenance costs mean you get dependable testing power without complex infrastructure or costly service contracts.

Step-by-step Guide

Analysis in Motion

Step-by-step Guide

Analysis in Motion

1

Place a new LanthaCell in the slide tray, then insert the tray into the LanthaLux.

2

Draw ~0.5 mL of sample into a syringe.

3

Insert the needle into the LanthaCell through the hole on top of the slide tray.

4

Click Inject. When the timer reaches zero, press the syringe plunger to inject.

5

When the test completes, remove and dispose of the syringe and LanthaCell according to lab safety procedures.

Trusted by Leading Scientific Research Institutions

Testimonials

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut nec tincidunt ligula, eu dictum nisi. Ut sed placerat dui. Morbi ac placerat metus. Nulla eleifend elit quam, at eleifend ipsum pharetra ornare.

Jameson R. 4

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut nec tincidunt ligula, eu dictum nisi. Ut sed placerat dui. Morbi ac placerat metus. Nulla eleifend elit quam, at eleifend ipsum pharetra ornare.

Jameson R. 3

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut nec tincidunt ligula, eu dictum nisi. Ut sed placerat dui. Morbi ac placerat metus. Nulla eleifend elit quam, at eleifend ipsum pharetra ornare.

Jameson R. 2

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut nec tincidunt ligula, eu dictum nisi. Ut sed placerat dui. Morbi ac placerat metus. Nulla eleifend elit quam, at eleifend ipsum pharetra ornare.

Jameson R.

Application Specific

Heavy Water
(D20) Purity

Heavy water purity is a critical spec across production, reuse, and logistics, yet verifying it quickly and confidently remains a challenge with traditional lab methods. Reliable purity measurement across the full range:

  • ±3 wt% from 0-90% D₂O
  • ±0.3 wt% from 90-100% D₂O

Ethanol Water Content

Water content is a critical spec for fuel-grade ethanol across production, storage, and transfer, yet verifying it quickly and confidently remains a bottleneck with traditional lab methods.

Custom Moisture Detection

Have a moisture problem we don’t list? Contact us to collaborate on application-specific moisture detection and discuss feasibility.

Comparative Overview

NMR FTIR DENSITY METER LANTHALUX®
Training Ph.D. Scientist Ph.D. Scientist Anyone Anyone
Sample Prep & Data Handling Complex Moderate to Complex Moderate to Minimal None
Analysis Time Mins to Hours Mins Mins < 30 Secs
Portability Designated Space Bench-top Only Bench-top Only Fully Portable
Maintenance Complex Moderate to Complex Minimal None
Impurity Inference Moderate Sensitivity Moderate Sensitivity Highly Sensitive Moderate Sensitivity
Power Requirement AC Power AC Power AC Power Battery-operated
LANTHALUX® NMR FTIR DENSITY METER
Training Anyone Ph.D. Scientist Ph.D. Scientist Anyone
Sample Prep & Data Handling None Complex Moderate to Complex Moderate to Minimal
Analysis Time < 30 Secs Mins to Hours Mins Mins
Portability Fully Portable Designated Space Bench-top Only Bench-top Only
Maintenance None Complex Moderate to Complex Minimal
Impurity Inference Moderate Sensitivity Moderate Sensitivity Moderate Sensitivity Highly Sensitive
Power Requirement Battery-operated AC Power AC Power AC Power

Performance Specifications

High precision across the full D₂O range, with ±0.4 wt% repeatability in high-purity samples.

Measures H₂O/D₂O from 0 to 99.9 wt% D₂O with confidence in all application-relevant ranges.

Fast, simple workflow: 0.5 mL sample, no extra reagents, and results in about 20 seconds.

Robust to common impurities and easy to keep calibrated using our convenient 12-standard calibration kits.

Get it now

Ready to See Lantha in Action?

Let us know that you are ready to experience effortless testing.

FAQs

Technical Performance

Workflow Considerations

Maintenance & Support

At the Core

PCM-22 is our fluorescent color-changing metal-organic framework that makes rapid, quantitative checks of solvent purity simple and reliable.